When you install heavy IT equipment, it is posing great amount of risks to valuable employees particularly if it’s done manually. This is the reason why you are making good decisions for making use of data center lift to do all the moving. But just before you buy any server lift, there are few points that you must be aware of and this is what will be discussed in the next lines.

Number 1. The device should be purpose built for data centers – as a matter of fact, there are 2 aspects that should be considered when it comes to this issue, one comes with the potential for policy or code violations and two pertains to suitability of server lifting device. A very common error is buying server lift device that is designed specifically for general purpose or to warehouse applications. Most of the time, they aren’t maneuverable easily in data center aisle, don’t have the mechanism to extend into rack for easy and safe installation and have inadequate braking system.

If ever the lift device is using hydraulic oil or fluids in any of the said mechanisms, then it might be violating data center policy. These codes as well as policies are intended to protect the equipment and people and must be followed strictly.
Figuring Out Servers

Number 2. Lift system should be able to insert equipment into racks – most of the general purpose lift system can lift equipment to the desired height but it is not able to hold it in place into rack while it’s fastened in position. To install heavy equipment with gap underneath, this is requiring technicians to firmly hold the device.
What Do You Know About Businesses

Lift system that could hold the equipment intact in the rack while it’s fastened is the only means to enable single technician to install the heavy equipment safely without requesting for help.

Number 3. Do not risk radio frequency interference – all IT equipment similar to switches, servers as well as power supplies are all governed by regulations for RFI or Radio Frequency Interference. Signals on the RFI could be caused by different electrical devices and the most common one is coming from powerful magnetic field that’s generated when stopping or starting electric motors. Magnetic surge near the communication equipment can result to data interference and in more extreme cases, can damage the equipment.

To be able to eliminate RFI damage, it is highly recommended to have a hand operated device. One with a high ratio gearing must be adequate for average staff to operate without facing much difficulty. In addition to that, the data center lift device should be rated in order to accept the weight of switches, power supplies, batteries and servers your company used today.